RECO Railway Equipment Co.
Home About RECO
Cragg Railchargers
EZ Gate Crossing Arms
Magnum Hot Air BlowersSno-Net Home Page

Magnum Switch Heater

Model 922 Heater Controller Systems for Tubular Heaters
and Spare Parts

480 VAC Single-Phase Models
(60 hz input, 28 kW output per switch maximum)
Number of Switches Part Number Circuit Breaker Size
1 922-11-X1* 100AMP
2 922-12-X1 150AMP
1 922-11-X2 100AMP
2 922-12-X2 150AMP
3 922-13-X2 225AMP
4 922-14-X2 300AMP
5 922-15-X2 400AMP
6 922-16-X2 450AMP
7 922-17-X2 500AMP
8 922-18-X2 600AMP
9 922-19-X2 700AMP
10 922-110-X2 800AMP
11 922-111-X2 800AMP
12 922-112-X2 900AMP
* -X1: Model numbers shown above include a steel enclosure. Specify the type of material and size of the enclosure by adding the proper suffix. For example: 922-11-01 is a 100 amp unit for one switch with a single door enclosure made of Cor-Ten steel. See separate section for proper suffix.

Return to top of page

480 VAC 3-Phase, 3-Wire Models
(60 hz input, 3-wire without wye neutral, 28 kW output per switch maximum)
Number of Switches Part Number Circuit Breaker Size
1 922-3T1-X1* 100AMP
2 922-3T2-X1 125AMP
1 922-3T1-X2 100AMP
2 922-3T2-X2 125AMP
3 922-3T3-X2 125AMP
4 922-3T4-X2 200AMP
5 922-3T5-X2 250AMP
6 922-3T6-X2 250AMP
7 922-3T7-X2 350AMP
8 922-3T8-X2 400AMP
9 922-3T9-X2 400AMP
10 922-3T10-X2 450AMP
11 922-3T11-X2 500AMP
12 922-3T12-X2 500AMP
* -X1: Model numbers shown above include a steel enclosure. Specify the type of material and size of the enclosure by adding the proper suffix. For example: 922-11-01 is a 100 amp unit for one switch with a single door enclosure made of Cor-Ten steel. See separate section for proper suffix.

Return to top of page

480 VAC 3-Phase, 4-Wire Models
(60 Hz input, 4-wire wye neutral, 28 kW output per switch)
Number of Switches Part Number Circuit Breaker Size
1 922-3N1-X1* 100AMP
2 922-3N2-X1 125AMP
1 922-3N1-X2 100AMP
2 922-3N2-X2 125AMP
3 922-3N3-X2 125AMP
4 922-3N4-X2 200AMP
5 922-3N5-X2 250AMP
6 922-3N6-X2 250AMP
7 922-3N7-X2 350AMP
8 922-3N8-X2 400AMP
9 922-3N9-X2 400AMP
10 922-3N10-X2 450AMP
11 922-3N11-X2 500AMP
12 922-3N12-X2 500AMP
* -X1: Model numbers shown above include a steel enclosure. Specify the type of material and size of the enclosure by adding the proper suffix. For example: 922-11-01 is a 100 amp unit for one switch with a single door enclosure made of Cor-Ten steel. See separate section for proper suffix.

Suffix -01 indicates a 36” x 30” x 8” single door enclosure, for 1 or 2 switches. Made of Cor-Ten steel. For pole or wall mounting.
Suffix -11 indicates a 36” x 30” x 8” single door enclosure, for 1 or 2 switches. Made of steel with gray baked enamel finish. For pole or wall mounting.
Suffix -02 indicates a 74” x 42” x 24” freestanding Cor-Ten steel enclosure with front and back doors. Foundation not included.
Suffix -12 indicates a 74” x 42” x 24” freestanding steel enclosure with front and back doors. Gray baked enamel paint. Foundation not included.
Suffix –5 indicates no enclosure is provided. Panel shipped crated.

Return to top of page

Replacement Parts for 922 Full/Half-Wave Control
Description Part Number
TD Relay TGR90317 45007
Output Contractor CR353FF2BB1 45152
Relay HC4-AC115V 4521-0400
Relay HC4-DC24V 4532-0204
SCR/Diode Package 48005
Fuse FWH 80 51.01
Fuse AGC 0.3A 5111-0100
Fuse MDA3 5111-0102
Fuse FNQ 2-1/2 5111-0602
Fuse PCB-3 51118
Open Heater Module 9228-0100E
Heater Fault Module 9228-0200H
Air Temp Sensor 9228-0250C
Relay Board 9228-0300K
Rail Temp Sensor 9228-0600G
Digital Thermostat Board 9228-0650H
Relay Board (less time delay relay) 9228-1800G
Relay Board with no relays or fault modules 9228-1810B
Control Board 9228-3401E
Control Board for individual control 9228-3404E
Conversion Package to replace No. 9228-3000 Control Board with a No. 9228-3401 Control Board 9228-3901D

Return to top of page


 
RECO   RAILWAY EQUIPMENT CO.
15400 Medina Rd, Plymouth, MN 55447-1473
Telephone: 763-972-2200 or 1-800-624-5794, Fax: 763-972-2900,
E-mail: sales@rwy.com

Entire Contents Copyright © by Railway Equipment Co. 2006-2009